| Product Title | Yuchai Series(50Hz) |
| Brand Name | Yuchai |
| Frequency | 50HZ |
| Power | 200-2000KW |
| Fuel | Natural/Biogas/Coal/Associated/ Industrial Waste Gas |
| Type | Open/Sound-proof/Containerized |
Yuchai gas generator sets cover a power range from 200kW to 2000kW and support multiple gas sources including natural gas, biogas, coal mine gas, associated gas, and industrial waste gas. All series use Yuchai's self-developed gas engines with a complete model lineup and wide adaptability. Known for robust construction, economy, and environmental protection, they are available in various installation types and widely used in biogas projects, coal mine gas utilization, industrial waste gas power generation, and regional energy stations.
| Technical parameters of Natural gas units | ||||||
| Genset Model | Unit model | Frequency(Hz) | Power(kw) | Speed(r/min) | Size(mm) | Weight(kg) |
| Y200N5 | YC6KG-200N5LC | 50 | 200 | 1500 | 3150×1320×1670 | 2910 |
| Y250N5 | YC6KG-250N5LC | 50 | 250 | 1500 | 3200×1320×1670 | 3030 |
| Y300N5 | YC6TG-300N5LC | 50 | 300 | 1500 | 3450×1400×1810 | 3650 |
| Y350N5 | YC6TDG-350N5LC | 50 | 350 | 1500 | 3550×1470×1910 | 4270 |
| Y400N5 | YC6TDG-400N5LC | 50 | 400 | 1500 | 3550×1470×1910 | 4390 |
| Y400N5 | YC6CG-400N5LC | 50 | 400 | 1500 | 4900×2560×2840 | 8690 |
| Y500N5 | YC6CG-500N5LC | 50 | 500 | 1500 | 4900×2560×2840 | 8890 |
| Y600N5 | YC6CG-600N5LC | 50 | 600 | 1500 | 4900×2560×2840 | 9030 |
| Y700N5 | YC12VTDG-700N5LC | 50 | 700 | 1500 | 5000×2560×2940 | 9050 |
| Y800N5 | YC12VTDG-800N5LC | 50 | 800 | 1500 | 5100×2560×2940 | 9350 |
| Y1000N5 | YC12VCG-1000N5LC | 50 | 1000 | 1000 | 6000×2600×3015 | 17500 |
| Y30N5 | YC4DG-30N5LC | 50 | 30 | 1500 | 1800×1000×1110 | 789 |
| Y50N5 | YC4DG-50N5LC | 50 | 50 | 1500 | 1840×1000×1110 | 826 |
| Y60N5 | YC4GG-60N5LC | 50 | 60 | 1500 | 1900×720×930 | 1100 |
| Y80N5 | YC6GG-80N5LC | 50 | 80 | 1500 | 2080×965×1525 | 1273 |
| Y90N5 | YC6GG-90N5LC | 50 | 90 | 1500 | 2280×980×1450 | 1370 |
| Y100N5 | YC6GG-100N5LC | 50 | 100 | 1500 | 2485×965×1525 | 1478 |
| Y150N5 | YC6MKG-150N5LC | 50 | 150 | 1500 | 2840×1230×1505 | 1903 |
| Y180N5 | YC6MKG-180N5LC | 50 | 180 | 1500 | 2900×1030×1780 | 2500 |
| Y200N5 | YC6KG-200N5LC | 50 | 200 | 1500 | 3600×1300×1780 | 3200 |
| Y250N5 | YC6KG-250N5LC | 50 | 250 | 1500 | 3600×1300×1780 | 3200 |
| Y250N5 | YC6TG-250N5LC | 50 | 250 | 1500 | 3270×1300×1760 | 3800 |
| Y350N5 | YC6TDG-350N5LC | 50 | 350 | 1500 | 3900×1850×2290 | 5500 |
| Y500N5 | YC6TFG-500N5LC | 50 | 500 | 1500 | 3600×1500×2100 | 7400 |
| Y500N5 | YC6CG-500N5LC | 50 | 500 | 1500 | 4107×1633×2111 | 8890 |
| Y600N5 | YC6CG-600N5LC | 50 | 600 | 1500 | 4107×1633×2111 | 8890 |
| Y700N5 | YC12VTDG-700N5LC | 50 | 700 | 1500 | 3880×2080×2370 | 8000 |
| Y700N5 | YC12VTDG-700N5HC | 50 | 700 | 1500 | 4415×2135×2130 | 9500 |
| Y800N5 | YC12VTDG-800N5LC | 50 | 800 | 1500 | 3880×2080×2370 | 8000 |
| Y800N5 | YC12VTDG-800N5HC | 50 | 800 | 1500 | 4415×2135×2130 | 9500 |
| Y1000N5 | YC12VCG-1000N5LC | 50 | 1000 | 1000 | 5210×2110×2660 | 16100 |
| Y1000N5 | YC12VCG-1000N5HC | 50 | 1000 | 1000 | 5510×2110×2660 | 17500 |
| Y1000N5 | YC16VTDG-1000N5LC | 50 | 1000 | 1500 | 4618×1992×2280 | 11700 |
| Y1000N5 | YC16VTDG-1000N5HC | 50 | 1000 | 1500 | 4918×1992×2280 | 12500 |
| Y1100N5 | YC16VTDG-1100N5LC | 50 | 1100 | 1500 | 4618×1992×2280 | 11700 |
| Y1100N5 | YC16VTDG-1100N5HC | 50 | 1100 | 1500 | 4918×1992×2280 | 12500 |
| Y1500N5 | YC16VCG-1500N5LC | 50 | 1500 | 1000 | 7138×2086×2790 | 22000 |
| Y1500N5 | YC16VCG-1500N5HC | 50 | 1500 | 1000 | 7138×2086×2790 | 22500 |
| Y2000N5 | YC16VCG-2000N5LC | 50 | 2000 | 1500 | 8416×2055×2890 | 24800 |
| Y2000N5 | YC16VCG-2000N5HC | 50 | 2000 | 1500 | 8834×2055×2890 | 25500 |
| Technical parameters of Biogas unit | ||||||
| Genset Model | Unit model | Frequency(Hz) | Power(kw) | Speed(r/min) | Size(mm) | Weight(kg) |
| Y200B5 | YC6KG-200B5LC | 50 | 200 | 1500 | 3150×1320×1670 | 2910 |
| Y250B5 | YC6TG-250B5LC | 50 | 250 | 1500 | 3450×1400×1810 | 4850 |
| Y300B5 | YC6TDG-300B5LC | 50 | 300 | 1500 | 7180×2400×2650 | 5500 |
| Y350B5 | YC6TDG-350B5LC | 50 | 350 | 1500 | 3550×1470×1910 | 5650 |
| Y400B5 | YC6CG-400B5LC | 50 | 400 | 1500 | 4900×2560×2840 | 8690 |
| Y500B5 | YC6CG-500B5LC | 50 | 500 | 1500 | 4900×2560×2840 | 8890 |
| Y700B5 | YC12VTDG-700B5LC | 50 | 700 | 1500 | 5000×2560×2940 | 9050 |
| Y800B5 | YC12VTDG-800B5LC | 50 | 800 | 1500 | 5100×2560×2940 | 9350 |
| Y250B5 | YC6TG-250B5LC | 50 | 250 | 1500 | 3270×1270×1760 | 3800 |
| Y300B5 | YC6TDG-300B5LC | 50 | 300 | 1500 | 3900×1850×2290 | 5500 |
| Y350B5 | YC6TDG-350B5LC | 50 | 350 | 1500 | 3900×1850×2290 | 5500 |
| Y400B5 | YC6CG-400B5LC | 50 | 400 | 1500 | 4107×1633×2111 | 8890 |
| Y500B5 | YC6CG-500B5LC | 50 | 500 | 1500 | 4107×1633×2111 | 8890 |
| Y500B5 | YC6CG-500B5HC | 50 | 500 | 1500 | 4107×1633×2111 | 8890 |
| Y700B5 | YC12VTDG-700B5LC | 50 | 700 | 1500 | 3880×2080×2370 | 8000 |
| Y700B5 | YC12VTDG-700B5HC | 50 | 700 | 1500 | 4415×2135×2130 | 9500 |
| Y800B5 | YC12VTDG-800B5LC | 50 | 800 | 1500 | 3880×2080×2370 | 8000 |
| Y800B5 | YC12VTDG-800B5HC | 50 | 800 | 1500 | 4415×2135×2130 | 9500 |
| Y1000B5 | YC12VCG-1000B5LC | 50 | 1000 | 1000 | 6180×2340×2640 | 17600 |
| Y1000B5 | YC12VCG-1000B5HC | 50 | 1000 | 1000 | 6180×2340×2640 | 18000 |
| Y1000B5 | YC12VCG-1000B5LC | 50 | 1000 | 1000 | 6000×2600×3015 | 17500 |
| Technical parameters of Coal gas unit | ||||||
| Genset Model | Unit model | Frequency(Hz) | Power(kw) | Speed(r/min) | Size(mm) | Weight(kg) |
| Y350C5 | YC6TDG-350M5LC | 50 | 350 | 1500 | 3550×1470×1910 | 4270 |
| Y400C5 | YC6CG-400M5LC | 50 | 400 | 1500 | 4900×2560×2840 | 8690 |
| Y500C5 | YC6CG-500M5LC | 50 | 500 | 1500 | 4900×2560×2840 | 8890 |
| Y1000C5 | YC12VCG-1000M5LC | 50 | 1000 | 1000 | 6000×2600×3015 | 17500 |
| Y1000C5 | YC12VCG-1000W5HC | 50 | 1000 | 1000 | 5975×2230×2660 | 18000 |
| Y1500C5 | YC16VCG-1500W5HC | 50 | 1500 | 1000 | 7138×2058×2775 | 21000 |
| Y2000C5 | YC16VCG-2000W5HC | 50 | 2000 | 1500 | 7430×2558×2916 | 26000 |
| Technical parameters of Associated Gas unit | ||||||
| Genset Model | Unit model | Frequency(Hz) | Power(kw) | Speed(r/min) | Size(mm) | Weight(kg) |
| Y1100A5 | YC16VCG-1100AP5LC | 50 | 1100 | 1000 | 8600×2100×2640 | 27500 |
| Y1100A5 | YC16VCG-1100AP5HC | 50 | 1100 | 1000 | 8630×2100×2640 | 28000 |
| Y1200A5 | YC16VCG-1200AP5LC | 50 | 1200 | 1000 | 8600×2100×2640 | 27500 |
| Y1200A5 | YC16VCG-1200AP5HC | 50 | 1200 | 1000 | 8630×2100×2640 | 28000 |
| Y1320A5 | YC16VCG-1320AP5LC | 50 | 1320 | 1000 | 8600×2100×2640 | 27500 |
| Y1320A5 | YC16VCG-1320AP5HC | 50 | 1320 | 1000 | 8630×2100×2640 | 28000 |
| Technical parameters of Industrial Waste Gas unit | ||||||
| Genset Model | Unit model | Frequency(Hz) | Power(kw) | Speed(r/min) | Size(mm) | Weight(kg) |
| Y1200I5 | YC16VCG-1200R5HC | 50 | 1200 | 1000 | 6950×2070×2890 | 22000 |
| Y1500I5 | YC16VCG-1500R5HC | 50 | 1500 | 1000 | 7100×2120×2800 | 23000 |