| Mahsulotning nomi | Cummins seriyasi (50/60 Hz) |
| Brend nomi | Komins |
| Quvvat | 30-3750 KVA / 35-4375 KVA |
| Yuq | ДИЗЕЛЬ |
| Turi | Ochiq / Ovozsiz / Konteynerlangan |
Cummins seriyasidagi gaz generatorlarining quvvat doirasi 30 KVA dan 1250 KVA gacha bo'ladi va ular tabiiy gaz hamda biogazdan foydalanishi mumkin. Yetilgan gaz elektr energiyasi ishlab chiqarish platformasiga ega bo'lganligi sababli, uning ishlashi barqaror va ishonchli. Ikki konfiguratsiya mavjud: ochiq ramka va yopiq turdagi quticha; ular kichik va o'rta miqyosli tijorat va sanoat gaz elektr energiyasi ishlab chiqarish hamda biogazdan foydalanish loyihalariga mos keladi.
|
Genset modeli (50Gts) |
Motor modeli | ESP | PRP | Voltaj | Koʻp uchraydiganlik | Bo'shliq | ||
| KVA | Kw | KVA | Kw | |||||
| C375N5 | K19N-G1 | / | / | 375 | 300 | 400/230 | 50 | N/A |
| C437.5N5 | K19N-G3 | / | / | 438 | 350 | 400/230 | 50 | N/A |
| C500N5 | K19N-G4 | / | / | 500 | 400 | 400/230 | 50 | N/A |
| C625N5 | K38N-G5 | / | / | 625 | 500 | 400/230 | 50 | N/A |
| C750N5 | K38N-G6 | / | / | 750 | 600 | 400/230 | 50 | N/A |
| C875N5 | K38N-G7 | / | / | 875 | 700 | 400/230 | 50 | N/A |
| C1000N5 | K38N-G8 | / | / | 1000 | 800 | 400/230 | 50 | N/A |
| C1125N5 | K50N-G9 | / | / | 1125 | 900 | 400/230 | 50 | N/A |
| C1250N5 | K50N-G10 | / | / | 1250 | 1000 | 400/230 | 50 | N/A |
| Genset modeli | Motor modeli |
Nominal Quvvat (kVt/KVA) |
Rezerv energiyasi (kVt/KVA) |
Nominal Jorov |
Silindir Yo'q. |
Teshik*Urish | Gaz iste'moli | |
| Tabiiy gaz | Biogaz | |||||||
| C30NB9 | 4BT3.9-G1 | 30/37.5 | 33/41.25 | 54 | 4.L | 102*120 | 0.33 | 0.55 |
| C40NB9 | 4BT3.9-G2 | 40/50 | 44/55 | 72 | 4.L | 102*120 | 0.33 | 0.55 |
| C50NB9 | 4BTA3.9-G2 | 50/62.5 | 55/68.75 | 90 | 6.L | 102*120 | 0.33 | 0.55 |
| C80NB9 | 6BTA5.9-G2 | 80/100 | 88/110 | 144 | 6.L | 102*120 | 0.33 | 0.55 |
| C100NB9 | 6BTAA5.9-G2 | 100/125 | 110/137.5 | 180 | 6.L | 102*120 | 0.33 | 0.55 |
| C120NB9 | 6BTAA5.9-G12 | 120/150 | 132/165 | 216 | 6.L | 102*120 | 0.33 | 0.55 |
| C150NB9 | 6CTA8.3-G2 | 150/187.5 | 165/206.25 | 270 | 6.L | 114*135 | 0.33 | 0.55 |
| C200NB9 | 6CTAA8.9-G2 | 200/250 | 220/275 | 360 | 6.L | 114*135 | 0.33 | 0.55 |
| C300NB9 | 6ZTAA13-G3 | 300/375 | 330/412.5 | 540 | 6.L | 130*163 | 0.33 | 0.55 |
| C400NB9 | KT38T | 400/500 | 440/550 | 720 | 6.L | 159*159 | 0.33 | 0.55 |
| C500NB9 | KTAA5.9-G6A | 500/625 | 550/687.5 | 900 | 6.L | 159*159 | 0.33 | 0.55 |
| C600NB9 | KTA38-G2 | 600/750 | 660/825 | 1080 | 12.V | 159*159 | 0.33 | 0.55 |
| C800NB9 | KTA38-G5 | 800/1000 | 880/1100 | 1440 | 12.V | 159*159 | 0.33 | 0.55 |
| C1100NB9 | KTA50-G8 | 1100/1375 | 1210/1512.5 | 1980 | 16.V | 159*159 | 0.33 | 0.55 |
| C1200NB9 | KTA50-GS8 | 1200/1500 | 1320/1650 | 2160 | 16.V | 159*159 | 0.33 | 0.55 |